Gas heaters with condensate drainage
EOLO BC
Gas heaters in the EOLO range are state-of-the-art heating solutions for industry, logistics and agriculture.
Comply with the requirements of the Directive ErP2021.
EOLO NBCs are used for heating and ventilation in large-scale buildings.
Comply with the requirements of the Directive ErP2021.
EOLO NBCs are used for heating and ventilation in large-scale buildings.


Gas heater
EOLO BC
EOLO NBC are equipped with high-efficiency heat exchangers, so that they are an efficient and economical heat source in large and medium-sized buildings. They can be mounted on walls and under ceilings (PS model).
Thanks to the efficient wentylators with a long blowing range effectively heat the halls production, warehouses and other large-scale facilities, providing thermal comfort and controlled conditions for stored materials and goods.
Why EOLO
Properties
EOLO NBCs are characterised by high energy efficiency and quiet operation. They are available in a wide range of heating capacities, allowing them to be precisely matched to the volume of the building. The robust design ensures long life and reliability in harsh industrial environments.
Heating power
16-103 kW
Condensate
With condensate drainage
NOx
<50 mg/kWh
Polish Production

Single fan panel
Back panel
Premix burner
Heat exchanger
Cartridge + air filter
How does it work?
Construction of EOLO BC
EOLO NBC underfloor heaters are equipped with exchangers condensate-free NBC type and modulating PREMIX burner.
Gas is combusted in the heat exchanger, generating heat energy. Powerful fans transport the thus heated air into the room. The air is directed in a vertical or near-vertical direction for the versions EOLO NBC AC with centrifugal fan. AE version is equipped with axial fan.
Designated models PS are designed for underfloor installation.
Designated models PS are designed for underfloor installation.
Technical table
Technical data
Check the technical data of the device.
EOLO BC model
15
25
35
45
55
65
85
100
Rated heat output
kW(Hi)
16
22
32
43
52
63
86
103
Minimum heat output
kW(Hi)
6
8
11
15
18
22
28
32
Combustion efficiency min.
%
105.1
104.8
105
105
104.9
105.1
103.9
103.9
Combustion efficiency nom.
%
95.8
94.9
95.1
95.2
97.1
97.2
97.5
97.7
Gas connection diameter
inch
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
Air intake diameter
mm
100
100
100
100
100
100
130
130
Diameter of flue gas discharge
mm
100
100
100
100
100
100
130
130
Electricity supply
V/Hz
230/50
230/50
230/50
230/50
230/50
230/50
230/50
230/50
Operating temperature
°C
-15: +40
-15: +40
-15: +40
-15: +40
-15: +40
-15: +40
-15: +40
-15: +40
Max. amount of condensate
l/h
0.5
0.4
1.0
1.1
1.6
2.1
3.2
2.9
AE series with axial fans
Electrical power
W
210
260
350
560
710
690
1120
1480
Number of fans
n.
1
1
1
1
1
2
2
2
Diameter of fans
mm
350
400
450
500
550
450
500
550
Air flow
m3/h
2 100
3 200
4 500
6 300
7 000
8 300
11 800
13 600
Min/max temperature rise
°C
8/22
7/20
7/20
7/20
8/21
8/22
7/21
7/22
Horizontal blowing range
m
10
13
19
23
27
27
30
AC series with centrifugal fans
Electrical power
W
440
500
520
1190
1290
1120
2260
2580
Number of fans
n.
1
1
1
1
1
2
2
2
Fan model
9/7
9/9
10/10
12/9
12/12
10/10
12/9
12/12
Air flow
m3/h
1 900
3 330
4 500
5 700
6 800
8 400
11 400
13 400
Min/max temperature rise
°C
9/25
7/21
7/21
7/21
7/22
7/22
7/22
7/23
Usable compression
Bye
150
150
150
150
150
150
150
150
Burner
VIP1 (a)
VIP1 (a)
VIP1 (a)
VIP1 (b)
VIP1 (c)
VIP1 (c)
VIP1 (d)
VIP2 (b)
Gas block
848 Sigma
848 Sigma
848 Sigma
848 Sigma
848 Sigma
848 Sigma
822 Nova Mix or VK4415
822 Nova Mix or VK4415
Gas blower
NRG 118
NRG 118
NRG 118
NRG 118
RG 148
RG 148
NRG 137 or FASCO GPM5.8
NRG 137 or FASCO GPM5.8
Why EOLO NBC?
Why is EOLO BC the ideal choice for your project?
Performance
The EOLO NBC gas heater provides fast and efficient heating. All EOLO heaters in the Systema Polska range meet the requirements of the ErP 2021 standard.
Evenly warm
Ideal for medium and large industrial halls. Even heating distribution - a powerful fan allows heated air to be distributed throughout the room, eliminating cold zones and ensuring optimal working and storage conditions.
Zoned heating possible
The controllers allow flexible adjustment of heating conditions in different parts of the building, resulting in energy savings.
Fast and effective action
The heat is felt almost as soon as the unit is activated, which is invaluable in halls with large volumes where a rapid rise in temperature is important.
Low heat costs
By using gas as a heat source, gas heaters keep heating costs low, even for large spaces.

Choose EOLO NBC
Choose EOLO BC
Optimise the heating of your space with EOLO NBC heaters! Contact us for a personalized quote!
Downloads
Download files
Need detailed information? Download technical documentation, data sheets or marketing material.